| Topic: Fastening Requirements | ||
DynaGlas® panels are always to be fastened to horizontal members (purlins in the roof, girts in the walls), never to vertical members; the latter do not provide the required cross support. Depending on the intensity of area wind and snow loads, purlins and girts should spaced approximately 4' or less apart. When high snow buildups are expected in gutters between houses, the distance to the first purlin should be approximately 3'.
No predrilling is required when using Palram fasteners. Other fasteners require predrilling, especially with darker colored panels. In order to avoid excessive local stress, it is important that DynaGlas not be fastened down too tightly. |
Screws should be tightened only to the point where the washer is seated firmly, no tighter. A power screwdriver with adjustable torque is strongly recommended.
DynaGlas panels can be fastened directly to purlins when the purlins have drip channels or when condensate drip at the purlins is not a problem. If a structure is equipped with a Palram DrainAway Condensate Control System, panels are fastened directly to the horizontal Collector members at the corrugation valleys. In the absence of a DrainAway System, if it is required that condensate drip at the purlins be minimized, and the purlins do not have drip channels, No-Drip Spacers must be placed between the purlins and the panels. The panels are then fastened at the top of the corrugation with 2" woodgrip or self-drilling screws. At the side and end walls, DynaGlas can be fastened directly to all girt members at the corrugation valleys. |
|
| Fastener Location | Req'd Fastener | Required Spacing |
| At gutters, eaves, aluminum vent bottom rails and at sills; at aluminum ridge, vent header and vent top rail without channel recesses for receiving DynaGlas. | #10 x 1" WG* or #12 x 1" SDTS** |
Every corrugation at corrugation valley (4 fasteners per lineal foot of supporting member) |
| At aluminum ridge, vent header and vent top rail with channel recesses for receiving DynaGlas. | #10 x 1" WG or #12 x 1" SDTS |
Every third corrugation at corrugation valley (1.5 fasteners per lineal foot of supporting member) |
| At purlins with condensation collection troughs, DrainAway Collectors and side wall girts; when or fastening DynaGlas directly to wood members without using No-Drip Spacers. (Note: 3/4 screw or is not long enough to be used in conjunction with a corrugated foam closure strip, a 1 screw must be used at this point). | #10 x 1" WG or #12 x 3/4" SDTS or #12 x 1" SDTS |
Every other corrugation at corrugation valley (2 fasteners per lineal of supporting member) |
| At wood or metal purlins when using No-Drip Spacers (No-Drip Spacers are not used at gutter or ridge). | #10 x 2" WG or #12 x 2" SDTS |
Every other corrugation at corrugation crown (2 fasteners per lineal of supporting member) |
| At vertical panel laps (using Self-Grip Lap Fastener assembly) | #10 x 1" WG (included in Self- Grip Lap Fastener Assembly) |
Every 18" to 20" (Approximately 1 assy. per 6 square feet of DynaGlas being used) |
| * WG = Woodgrip Screw **SDTS = Self Drilling Tapping Screw Note: DynaGlas corrugation pitch is 3 O.C. | ||